Rated Current
Cantidad
1

$49.95

Precio final con envío
Envío gratis

Desglose de costo

Precio del producto
$48.37
Fee de Servicio MiCyberCompras
$1.58
Costo de envío estimado
Gratis
Costo Final Garantizado:
$49.95

El impuesto, si aplica, se confirma en el checkout según tu dirección. Aquí ves producto, fee y envío.

  • Envío EE.UU.: USPS / UPS Ground.

  • Costo Visible: Sin sorpresas ocultas.

  • Tracking Real: Alertas por SMS/Email.

  • Pago Seguro: Cifrado por Stripe.

¿Por qué elegir MiCyberCompras?

Atributos del productoBrand Name: GEYA, Does it include wireless functionality?: No, Does it include a Battery?: No, High-concerned chemical: none, EU LVD Voltage: Low voltage: Below 50Vac or 75Vdc, Type: Mini, Origin: Mainland China, Rated Voltage: 220V, is_customized: Yes, Type: Circuit breaker, Model Number: G2R NEW MINI ATS, Is Smart Device: no, Certification: CE
Tamaño del paquete150×150×120 mm

GEYA G2R Din Rail 2P 4P ATS Dual Power Automatic Transfer Switch Electrical Selector Switches Uninterrupted Power 63A

General


The GEYA G2R is a automatic transfer switch that ensures reliable power switching, automatically switches to backup power when the main power fails, with adjustable voltage protection and delay settings, suitable for household and industrial emergency power supply scenarios.


ATS Transfer Mode

Main Power⇆Backup Power

Available Combinations

City Power ⇆ Generator

PV Inverter Output AC Power ⇆ City Power/Generator (Inverter Rated Power > 3000W)


Note: For stable and reliable switching, the connected PV inverter must be a Pure Sine Wave type with a rated power > 3000W.

Normally, pull the selector switch to the automatic position. When manual operation is required, pull the selector switch to the manual position. After manual operation is complete, pull the selector switch from the manual position to the automatic position.The control circuit TSE is immediately energized.

After the change over is completed, the internal switch will damage the coil in the control circuit, and the coil can work normally at 85%-110% of the rated operating voltage. Too low input voltage may cause the coil to overheat and burn out.

Voltage Protection Parameters

220V G2R:Undervoltage Value 175V, Recovery Value 190V

                     Overvoltage  Value 270V, Recovery Value 250V

Delay: Trip: 10s; Reset: 30s


When the voltage is normal, the two LEDs stay on constantly.

When the voltage is abnormal

voltage abnormality: Switches to standby power after a 10-second delay (default setting).

Overvoltage status: LED flashes twice every 2 seconds.

Undervoltage status: LED flashes once every 2 seconds.

voltage abnormality: LED displays a breathing effect (10-second default). It dims gradually during undervoltage and brightens gradually during overvoltage.


Attention!When manual operation the mode selection switch must be in "manual" position.